Skip to search boxSkip to navigationSkip to main content

Reproducibility of the measurement of central corneal thickness in healthy subjects obtained with the optical low coherence reflectometry pachymeter and comparison with the ultrasonic pachymetry

  • ,
  • Eduardo Plancarte-Lozano
    ,
  • Agustín Del Valle-Penella
    ,
  • María de Lourdes Guzmán-Martínez
    ,
  • Andrés Villarreal-González
  • Secretaria de Salud del Estado de N.L.
    ,
  • DebRA Mexico Foundation
    ,
  • Fundación Destellos de Luz. Monterrey
    ,
  • Medical Sciences Head Office
    ,
  • Division of Health Sciences
Research Output:
Contribution to journal
Review article
Peer-review

Publication metrics

Metrics

SciVal
Citations
3
Scopus
Citations
SciVal
FWCI
0.09
SciVal
Author count
5
SciVal
Paper percentile
28

Abstract

Background: Corneal pachymetry is widely used for refractive surgery and follow up in keratoconus, accurate measurement is essential for a safe surgery.

Objective: To assess intraobserver reliability of central corneal thickness (CCT) measurements using optical low-coherence reflectometry (OLCR) technology and its agreement with ultrasonic pachymeter (US).

Method: Randomized and prospective comparative evaluation of diagnostic technology. One randomly healthy eye of subjects was scanned three times with both devices. Intraobserver within-subject standard deviation (Sw), coefficient of variation (CVw) and intraclass correlation coefficient (ICC) were obtained for reliability analysis; for study agreement, data were analyzed using the paired-sample t test and the Bland-Altman LoA method. The mean of three scans of each equipment was used to assess the LoA.

Results: The study enrolled 30 eyes of 30 subjects with average age of 28.70 ± 8.06 years. For repeatability, the Sw were 3.41 and 5.96 µ, the intraobserver CVw was 2 and 4% and ICC 0.991 and 0.988, for OLCR and US respectively. The mean CCT difference between OLCR and US was 8.90 ± 9.03 µ (95% confidence interval: 5.52-2.27 µ), and the LoA was 35.40 µ.

Conclusions: OLCR technology provided reliable intraobserver CCT measurements. Both pachymetry measurements may be used interchangeably with minimum calibration adjustment.

Publication Information

Output type

Research Output:
Contribution to journal
Review article
Peer-review

Original language

Spanish

Pages from-to (Number of pages)

Pages 44-49 (6 pages)

Journal (Volume, Issue Number)

Cirugia y Cirujanos (Volume 86, Issue 1)

Publication milestones

  • Published - 2019

Publication status

Published - 2019

ISSN

0009-7411

Publication IDs

  • Scopus: 85064312980
  • Scopus: 85054137421
  • PubMed: 29681640
  • Scopus: 85054137421
  • WOS: 000510014400007
  • PubMed: 30951042