Comparative study of the measurement of central corneal power using the manual keratometer, the IOLMaster® and Sirius® tomography
Original title: Estudio comparativo de la medición del poder corneal central usando el queratómetro manual, el IOLMaster® y el tomógrafo Sirius®
- Manuel Garza-León(corresponding author),
- Paola de la Parra-Colín,
- Tonatiuh Barrientos-Gutierrez
- Fundación Destellos de Luz,
- Dirección de Ciencias Médicas de la División de Ciencias de la Salud,
- Instituto Mexicano del Seguro Social,
- Instituto Nacional de Salud Publica
Research Output:
Contribution to journal
Article
Peer-reviewPublication metrics
Metrics
SciVal
FWCI
0.16
SciVal
Author count
3
SciVal
Citations
3
SciVal
Paper percentile
36
Abstract
Objective: To assess the repeatability and comparability of the central keratometric power measurements obtained from a novel Scheimpflug camera with a Placido-disc topographer (Sirius®), manual keratometer and IOLMaster®. Material and methods: In a sample of 30 unoperated eyes of healthy subjects, the central corneal power was analyzed by a single examiner using the Sirius®, the manual keratometer and the IOLMaster®. Repeatability of 3 sets of measurements from each device were evaluated using the coefficient of variation, standard deviation, and intraclass correlation coefficient. T-test with Bonferrioni adjustment and Bland and Altman plots were used to assess agreement between devices. Results: All instruments showed high reproducibility with coefficient of variation less than 0.30% for all measurements (0.291% and 0.237%, 0.238% and 0.361%, 0.238% and 0.208% for the flattest (FK) and steepest keratometry of Sirius®, manual keratometer and IOLMaster® respectively) and a higher intraclass correlation coefficient of 0.95 in all measurements. The manual keratometer has the lowest keratometric power (FK 41,988 and SK 43,277 D), followed by Sirius® (FK 42.285 D and SK 43.510 D) and finally the IOLMaster® (FK 42.483 D and SK 43.763 D), with a statistically significant differences. Conclusion: In the assessment of normal corneas, central corneal power measured with this 3 devices showed high repeatability however there was no agreement between the equipments and the differences were statistically significant.
Publication Information
Output type
Research Output:
Contribution to journal
Article
Peer-reviewOriginal language
SpanishPages from-to (Number of pages)
Pages 111-117 (7 pages)Journal (Volume, Issue Number)
Revista Mexicana de Oftalmologia (Volume 90, Issue 3)Publication milestones
- Published - 01/05/2016
Publication status
Published - 01/05/2016
ISSN
0187-4519Publication IDs
- Scopus: 84965076572
- Scopus: 84965076572