Comparative study of the measurement of central corneal power using the manual keratometer, the IOLMaster® and Sirius® tomography

Original title: Estudio comparativo de la medición del poder corneal central usando el queratómetro manual, el IOLMaster® y el tomógrafo Sirius®
  • Manuel Garza-León(corresponding author)
    ,
  • Paola de la Parra-Colín
    ,
  • Tonatiuh Barrientos-Gutierrez
*Corresponding author for this work
  • Fundación Destellos de Luz
    ,
  • Dirección de Ciencias Médicas de la División de Ciencias de la Salud
    ,
  • Instituto Mexicano del Seguro Social
    ,
  • Instituto Nacional de Salud Publica
Research Output:
Contribution to journal
Article
Peer-review

Publication metrics

Metrics

SciVal
FWCI
0.16
SciVal
Author count
3
SciVal
Citations
3
SciVal
Paper percentile
36
Scopus
Citations

Abstract

Objective: To assess the repeatability and comparability of the central keratometric power measurements obtained from a novel Scheimpflug camera with a Placido-disc topographer (Sirius®), manual keratometer and IOLMaster®. Material and methods: In a sample of 30 unoperated eyes of healthy subjects, the central corneal power was analyzed by a single examiner using the Sirius®, the manual keratometer and the IOLMaster®. Repeatability of 3 sets of measurements from each device were evaluated using the coefficient of variation, standard deviation, and intraclass correlation coefficient. T-test with Bonferrioni adjustment and Bland and Altman plots were used to assess agreement between devices. Results: All instruments showed high reproducibility with coefficient of variation less than 0.30% for all measurements (0.291% and 0.237%, 0.238% and 0.361%, 0.238% and 0.208% for the flattest (FK) and steepest keratometry of Sirius®, manual keratometer and IOLMaster® respectively) and a higher intraclass correlation coefficient of 0.95 in all measurements. The manual keratometer has the lowest keratometric power (FK 41,988 and SK 43,277 D), followed by Sirius® (FK 42.285 D and SK 43.510 D) and finally the IOLMaster® (FK 42.483 D and SK 43.763 D), with a statistically significant differences. Conclusion: In the assessment of normal corneas, central corneal power measured with this 3 devices showed high repeatability however there was no agreement between the equipments and the differences were statistically significant.

Publication Information

Output type

Research Output:
Contribution to journal
Article
Peer-review

Original language

Spanish

Pages from-to (Number of pages)

Pages 111-117 (7 pages)

Journal (Volume, Issue Number)

Revista Mexicana de Oftalmologia (Volume 90, Issue 3)

Publication milestones

  • Published - 01/05/2016

Publication status

Published - 01/05/2016

ISSN

0187-4519

Publication IDs

  • Scopus: 84965076572
  • Scopus: 84965076572