Comparison of corneal thickness measurement with the pachymeter included in the Wavelight® EX500 Excimer Laser and the Scheimpflug camera tomograph Pentacam® in healthy subjects
Original title: Comparación de la medición del grosor corneal central medido con el paquímetro incluido en el Wavelight® Ex500 Excimer Laser y el tomógrafo de cámara de Scheimpflug Pentacam® en sujetos sanos.
- Manuel Garza León(corresponding author),
- Agustín del Valle-Penella,
- Bárbara Elizondo-Fernández,
- Perla Ortega-Zárate,
- María Fernanda Siller-Reyes
- Fundación Destellos de Luz,
- Dirección de Ciencias Médicas de la División de Ciencias de la Salud
Research Output:
Contribution to journal
Article
Peer-reviewPublication metrics
Metrics
Abstract
© 2016 Sociedad Mexicana de Oftalmología Objective Comparing the central corneal thickness measurements obtained by the pachymeter included in the Wavelight EX 500 Excimer Laser®and the Pentacam Scheimpflug®based tomography. Material and methods In a sample of thirty unoperated eyes of healthy subjects, the central corneal thickness was analyzed by a single examiner, prior to the measurements eyes was randomized. Three sets of measurements from each device were evaluated and statistical analysis was based on the averages of the measurements. For the correlation between both devices, T-test with Bonferrioni adjustment and Bland and Altman plots were used to assess agreement between devices. Results 30 healthy subjects were evaluated with a mean age of 28.7 ± 8.06 years (range 19-49 years), of which 12 were men. The right eye was randomized in 40% of patients. The average corneal thickness was 553.31 ± 32.47 μm and 554.53 ± 30.83 μm for WaveLight and Pentacam respectively, the difference was not statistically significant (P = .369). The difference in the average CCT was -1.2 microns (WaveLight-Pentacam) with a confidence interval of 95% from –3.96 to 1.51 microns. Conclusions Our results demonstrate that the pachymeter included in the Wavelight®EX500 Excimer Laser is a good alternative to the Pentacam pachymetry in the measurement measure of central corneal thickness in healthy patients.
Publication Information
Output type
Research Output:
Contribution to journal
Article
Peer-reviewOriginal language
SpanishPages from-to (Number of pages)
Pages 25-29 (5 pages)Journal (Volume, Issue Number)
Revista Mexicana de Oftalmologia (Volume 91, Issue 1)Publication milestones
- Published - 01/01/2017
Publication status
Published - 01/01/2017
ISSN
0187-4519Publication IDs
- Scopus: 85012050383
- Scopus: 85012050383