Skip to search boxSkip to navigationSkip to main content

Anatomical, biomechanical and aberrometric corneal characteristics of patients with Marfan syndrome

Original title: Características anatómicas, biomecánicas y aberrométricas de la córnea de pacientes con síndrome de Marfan
  • Destellos de Luz Non-profit Foundation
Research Output:
Contribution to journal
Article
Peer-review

Open access

Publication metrics

Metrics

SciVal
Citations
1
SciVal
Author count
1
SciVal
Paper percentile
31
Scopus
Citations

Abstract

Objective: To know the anatomical (mean keratometry, central pachimetry), optic (corneal aberrations represented by Zernike polynomials) and biomechanical (corneal hysteresis, and corneal resistance factor) characteristics in patients with Marfan syndrome. Material and methods: Prospective, transversal and observational study. We study patients with confirmed diagnosis of Marfan syndrome. The anatomical and aberrometrical characteristics was measured with otating Scheimpflug Camera (Pentacam, Oculus) and the biomechanical characteristics with ocular response analyzer (Reichert). The ocular response analyzer measures was made 4 times and represented by his average. All the studies was made by the same examiner. Results: Twenty eyes of 10 patients with confirmed diagnosis of Marfan syndrome was studied. 60% was male with an average age of 24 ± 10.79 years (range, 11-39). Three eyes of 2 patients was aphakic because a spontaneous posterior lens dislocation, of the other 17 eyes 100% subluxation of the lens. Mean simK was 40.49 ± 1.54 D (range, 38.7-42.7) 80% had less than 42 D. Average central corneal thickness was 562 ± 37.23 μm (range 506-626 μm). All the patients had a patological aberration coefficient 1.55 ± 0.37 (range, 1.1-2.5). Corneal hysteresis was 9.13 ± 1.49 mmHg (range, 7.1-12) and corneal resistance factor 9.09 ± 2.41 mmHg (range, 4.8-13.6). Conclusions: In our studied group, the corneas of Marfan syndrome patients presents a flat corneas with a normal pachymetry and biomechanical properties but with a abnormal aberration coefficient values.

Publication Information

Output type

Research Output:
Contribution to journal
Article
Peer-review

Original language

Spanish

Pages from-to (Number of pages)

Pages 93-97 (5 pages)

Journal (Volume, Issue Number)

Revista Mexicana de Oftalmologia (Volume 89, Issue 2)

Publication milestones

  • Published - 01/01/2015

Publication status

Published - 01/01/2015

ISSN

0187-4519

Publication IDs

  • Scopus: 84937963243