Skip to search boxSkip to navigationSkip to main content

Impact of bilateral nasal polyposis on the interoptic and interzygomatic distance

  • José Luis Treviño-Gonzáleza(Author)
    ,
  • Mario Alberto Campos-Coya(Author)
    ,
  • Mario Jesús Villegas-Gonzáleza(Author)
    ,
  • Josefina Alejandra Morales-Del Ángela(Author)
    ,
  • German A Soto-Galindoa(Author)
    ,
  • Masao Yamamoto-Ramosa(Author)
  • aUniversidad Autónoma de Nuevo León, Facultad de Medicina, Hospital Universitario "Dr. José Eleuterio González", Monterrey, Nuevo León, Mexico.
    ,
  • bNational Council of Science and Technology (CONACYT)
    ,
  • cTecnológico Nacional de México, Mexico City
    ,
  • dMathematical Investigation Center (CIMAT)
Research Output: Contribution to journal Article Peer-review

Publication metrics

Metrics

SciVal
Author count
10
SciVal
Paper percentile
25

PlumX, opens in new tab

Mentions
1
Captures
14

Abstract

Purpose To identify and determine variations on eye distance in patients with bilateral nasal polyposis (BNP) compared to a healthy control group. Methods This is a case-control study that included 20 BNP patients and 40 healthy controls. We included all patients with BNP confirmed by pathology and a computed tomography scan. A healthy control group was admitted, filtered by the exclusion criteria of nasal polyposis, craniofacial malformations, and encephalocele. Paranasal sinus CT scans were performed in all participants, and two measures were evaluated, the interoptic (soft tissue) and the interzygomatic (bone structure) distances. Results A total of 20 BNP subjects, 13 (65%) male and 7 (35%) female, with a mean age of 38.8 years, and 40 healthy controls, 16 (40%) male and 24 (60%) female with a mean age of 43.2 years, were included. The mean interoptic distance was 69.7 mm (71.9 mm men, 66.4 mm women) and interzygomatic distance was 103.1 mm (104.5 mm men, 100.6 mm women). A significant increase of the interoptic (p < 0.001) and interzygomatic (p < 0.002) measurements was found in patients with polyposis compared to the controls. In the receptor operative curve analysis, the interoptic distance had an area under a curve of 96% and the threshold that maximizes the sensitivity and specificity was 59.85 mm (sensitivity 90%, specificity 95%, PPV 90%, NPV 95%). Conclusions An increase in ocular and orbital distances was identified in patients with BNP. Polyposis may be identified by measuring eye separation. The established cut point distance identifies patients that may benefit from follow-up. Further research in this study line is suggested.

Publication Information

Output type

Research Output: Contribution to journal Article Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 1701-1705 (5 pages)

Journal (Volume, Issue Number)

Archiv fur klinische und experimentelle Ohren- Nasen- und Kehlkopfheilkunde (Volume 276, Issue 6)

Publication milestones

  • Accepted/In press - 2019
  • Published - 06/2019

Publication status

Published - 06/2019

ISSN

0003-9195

External Publication IDs

  • PubMed: 30895433
  • Scopus: 85063200617