Repeatability and comparability of anterior segment biometry obtained by the Sirius and the Pentacam analyzers

Paola De La Parra-Colín, Manuel Garza-León, Tonatiuh Barrientos-Gutierrez

Research output: Contribution to journalArticle

28 Citations (Scopus)

Abstract

To assess the repeatability and comparability of six anterior segment biometry parameters obtained with a novel Scheimpflug camera with a Placido disc topographer (Sirius) and slit-scanning tomography with a Scheimpflug camera (Pentacam), in a sample of 16 unoperated eyes of healthy subjects. The anterior segment was analyzed by a single examiner using the Sirius and the Pentacam analyzers. Mean simulated keratometry (Sim K), flat and steep axis keratometry (Kfand Ks), central and thinnest corneal thicknesses (CCT and TCT), and anterior chamber depth (ACD) measurements were evaluated. Repeatability of three sets of measurements from each device was assessed using the coefficient of variation (CV), within-subject standard deviation, and intraclass correlation coefficient (ICC). Bonferroni-adjusted t-tests, and Bland and Altman plots were used to establish agreement between devices. For both devices the CV of repeated measurements was <0.79 %. The ICC was >0.95 in all measurements except for Sirius Ks(ICC = 0.869). For all parameters evaluated, the Pentacam systematically yielded higher values, although differences were statistically significant in only three parameters-0.31 diopters for Ks, 10.1 μm for CCT and 12.4 μm for TCT. In the assessment of normal corneas both devices showed overall high repeatability. Although good agreement was found in three parameters (Sim K, Kfand ACD) these devices do not seem to be interchangeable for pachymetric determination. © 2013 Springer Science+Business Media.
Original languageEnglish
Pages (from-to)27-33
Number of pages7
JournalInternational Ophthalmology
DOIs
Publication statusPublished - 1 Jan 2014
Externally publishedYes

Fingerprint

Biometry
Equipment and Supplies
Anterior Chamber
Cornea
Healthy Volunteers
Tomography

All Science Journal Classification (ASJC) codes

  • Ophthalmology

Cite this

@article{898ae8f4b44b4074aab28405b62ebfc5,
title = "Repeatability and comparability of anterior segment biometry obtained by the Sirius and the Pentacam analyzers",
abstract = "To assess the repeatability and comparability of six anterior segment biometry parameters obtained with a novel Scheimpflug camera with a Placido disc topographer (Sirius) and slit-scanning tomography with a Scheimpflug camera (Pentacam), in a sample of 16 unoperated eyes of healthy subjects. The anterior segment was analyzed by a single examiner using the Sirius and the Pentacam analyzers. Mean simulated keratometry (Sim K), flat and steep axis keratometry (Kfand Ks), central and thinnest corneal thicknesses (CCT and TCT), and anterior chamber depth (ACD) measurements were evaluated. Repeatability of three sets of measurements from each device was assessed using the coefficient of variation (CV), within-subject standard deviation, and intraclass correlation coefficient (ICC). Bonferroni-adjusted t-tests, and Bland and Altman plots were used to establish agreement between devices. For both devices the CV of repeated measurements was <0.79 {\%}. The ICC was >0.95 in all measurements except for Sirius Ks(ICC = 0.869). For all parameters evaluated, the Pentacam systematically yielded higher values, although differences were statistically significant in only three parameters-0.31 diopters for Ks, 10.1 μm for CCT and 12.4 μm for TCT. In the assessment of normal corneas both devices showed overall high repeatability. Although good agreement was found in three parameters (Sim K, Kfand ACD) these devices do not seem to be interchangeable for pachymetric determination. {\circledC} 2013 Springer Science+Business Media.",
author = "{De La Parra-Col{\'i}n}, Paola and Manuel Garza-Le{\'o}n and Tonatiuh Barrientos-Gutierrez",
year = "2014",
month = "1",
day = "1",
doi = "10.1007/s10792-013-9780-0",
language = "English",
pages = "27--33",
journal = "International Ophthalmology",
issn = "0165-5701",
publisher = "Springer Netherlands",

}

Repeatability and comparability of anterior segment biometry obtained by the Sirius and the Pentacam analyzers. / De La Parra-Colín, Paola; Garza-León, Manuel; Barrientos-Gutierrez, Tonatiuh.

In: International Ophthalmology, 01.01.2014, p. 27-33.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Repeatability and comparability of anterior segment biometry obtained by the Sirius and the Pentacam analyzers

AU - De La Parra-Colín, Paola

AU - Garza-León, Manuel

AU - Barrientos-Gutierrez, Tonatiuh

PY - 2014/1/1

Y1 - 2014/1/1

N2 - To assess the repeatability and comparability of six anterior segment biometry parameters obtained with a novel Scheimpflug camera with a Placido disc topographer (Sirius) and slit-scanning tomography with a Scheimpflug camera (Pentacam), in a sample of 16 unoperated eyes of healthy subjects. The anterior segment was analyzed by a single examiner using the Sirius and the Pentacam analyzers. Mean simulated keratometry (Sim K), flat and steep axis keratometry (Kfand Ks), central and thinnest corneal thicknesses (CCT and TCT), and anterior chamber depth (ACD) measurements were evaluated. Repeatability of three sets of measurements from each device was assessed using the coefficient of variation (CV), within-subject standard deviation, and intraclass correlation coefficient (ICC). Bonferroni-adjusted t-tests, and Bland and Altman plots were used to establish agreement between devices. For both devices the CV of repeated measurements was <0.79 %. The ICC was >0.95 in all measurements except for Sirius Ks(ICC = 0.869). For all parameters evaluated, the Pentacam systematically yielded higher values, although differences were statistically significant in only three parameters-0.31 diopters for Ks, 10.1 μm for CCT and 12.4 μm for TCT. In the assessment of normal corneas both devices showed overall high repeatability. Although good agreement was found in three parameters (Sim K, Kfand ACD) these devices do not seem to be interchangeable for pachymetric determination. © 2013 Springer Science+Business Media.

AB - To assess the repeatability and comparability of six anterior segment biometry parameters obtained with a novel Scheimpflug camera with a Placido disc topographer (Sirius) and slit-scanning tomography with a Scheimpflug camera (Pentacam), in a sample of 16 unoperated eyes of healthy subjects. The anterior segment was analyzed by a single examiner using the Sirius and the Pentacam analyzers. Mean simulated keratometry (Sim K), flat and steep axis keratometry (Kfand Ks), central and thinnest corneal thicknesses (CCT and TCT), and anterior chamber depth (ACD) measurements were evaluated. Repeatability of three sets of measurements from each device was assessed using the coefficient of variation (CV), within-subject standard deviation, and intraclass correlation coefficient (ICC). Bonferroni-adjusted t-tests, and Bland and Altman plots were used to establish agreement between devices. For both devices the CV of repeated measurements was <0.79 %. The ICC was >0.95 in all measurements except for Sirius Ks(ICC = 0.869). For all parameters evaluated, the Pentacam systematically yielded higher values, although differences were statistically significant in only three parameters-0.31 diopters for Ks, 10.1 μm for CCT and 12.4 μm for TCT. In the assessment of normal corneas both devices showed overall high repeatability. Although good agreement was found in three parameters (Sim K, Kfand ACD) these devices do not seem to be interchangeable for pachymetric determination. © 2013 Springer Science+Business Media.

U2 - 10.1007/s10792-013-9780-0

DO - 10.1007/s10792-013-9780-0

M3 - Article

SP - 27

EP - 33

JO - International Ophthalmology

JF - International Ophthalmology

SN - 0165-5701

ER -