An electrical stimulation system for research and testing

Martha Salomé López De La Fuente, José Antonio Benavides Gómez

Research output: Contribution to conferencePaper

1 Citation (Scopus)

Abstract

Electrical stimulation is used in several research areas: In medicine, tissue and fluid samples are stimulated for cancer detection; in prosthetics, new devices are tested before commercial use; in genetics, for DNA manipulation; in food and water, for pathogen detection; in immunology for altered cells detection, and so on. In these research areas there is a need for a flexible and easy to use stimulation system that automates the testing and experimentation process. An autonomous, flexible, configurable, programmable and portable prototype has been developed to provide multiple stimulation signals and patterns for specific time periods and configurable tests. This work shows a programmable, configurable electric stimulator for providing outputs of up to 200Vpp in a frequency range of 1Hz to 40 kHz, in 4 different waveforms: sine, triangle, saw-tooth and square. The output voltage can be a single, dual, or superimposed signal of any combination of the 4 available waveforms, in a continuous or segmented pattern, with or without a frequency sweep.

Original languageEnglish
Pages78-82
Number of pages5
DOIs
Publication statusPublished - 1 Dec 2012
EventProceedings - 2012 9th Electronics, Robotics and Automotive Mechanics Conference, CERMA 2012 -
Duration: 1 Dec 2012 → …

Conference

ConferenceProceedings - 2012 9th Electronics, Robotics and Automotive Mechanics Conference, CERMA 2012
Period1/12/12 → …

Bibliographical note

Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.

All Science Journal Classification (ASJC) codes

  • Artificial Intelligence
  • Automotive Engineering

Fingerprint

Dive into the research topics of 'An electrical stimulation system for research and testing'. Together they form a unique fingerprint.

Cite this