Projects per year
Personal profile
Education/Academic qualification
Optics, Ph.D, STUDY OF SURFACE MECHANICAL PARAMETERS ON COMPOSITE BIOLOGICAL STRUCTURES BY USING NON-DESTRUCTIVE OPTICAL TESTS, Centro de Investigaciones en Optica
2013 → 2019
Nivel SNI
- Candidato
Fingerprint
- 1 Similar Profiles
Network
-
Optical Coherence Tomography Digital Image Processing for Meibomian Glands detection in patients with Dry Eye Disease Syndrome
Tavera Ruiz, C. G. & Garza León, M. A.
1/11/21 → 1/11/23
Project: Research project
File -
Estudio de factibilidad de la grabación de escenarios clínicos reales con tecnología de gafas inteligentes para la enseñanza de la práctica clínica en la Escuela de Medicina de la UDEM
Tavera Ruiz, C. G., Vidaltamayo, R., Basora Marimon, A., León Domínguez, U. & Huerta Ortiz, M. E.
1/3/23 → 1/3/24
Project: Research project
-
Photoelasticity for Stress Concentration Analysis in Dentistry and Medicine
Marin-Miranda, M., Wintergerst, A. M., Moreno Vargas, Y. A., Tavera Ruiz, C. G. & Juárez López, M. L. A., Oct 2022, In: Materials. 15, 19, p. 1 20 p., 6819.Research output: Contribution to journal › Review article › peer-review
Open Access1 Citation (Scopus) -
Cortical bone quality affectations and their strength impact analysis using holographic interferometry
Tavera Ruiz, C. G., 1 Oct 2018, In: Biomedical Optics Express. 9, 10, p. 4818-4833 16 p.Research output: Contribution to journal › Article › peer-review
Open Access24 Citations (Scopus) -
Laser vibrometry in the quality control of the break of tanned leather
Jorge Sanchez Preciado & Tavera Ruiz, C. G., May 2018, In: Optics and Lasers in Engineering. 104, p. 78-83 6 p.Research output: Contribution to journal › Article › peer-review
4 Citations (Scopus) -
Study of the cortical bone strength affectation due dehydration
Tavera Ruiz, C. G., 7 Sep 2018, Speckle 2018: VII International Conference on Speckle Metrology: VII International Conference on Speckle Metrology. Jaroszewicz, L. R. & Kujawinska, M. (eds.). p. 24 1083417. (Proceedings of SPIE - The International Society for Optical Engineering; vol. 10834).Research output: Chapter in Book/Report/Conference proceeding › Conference contribution
1 Citation (Scopus) -
Surface structural damage study in cortical bone due to medical drilling
Tavera Ruiz, C. G., De la Torre, M. H., Flores, J. M., Hernandez, M. D. S., Mendoza Santoyo, F., De Briones, M. J. R. & Sanchez, J. P., 1 May 2017, In: Applied Optics. 56, 13, p. F179-F188Research output: Contribution to journal › Article › peer-review
10 Citations (Scopus)
Activities
- 1 Invited talk
-
Luminic Interference, "The non-contact measuring art"
Cesar Giovani Tavera Ruiz (Speaker)
30 Nov 2018Activity: Talk or presentation types › Invited talk